{"title":"JA-111A base","description":"\u003ch2 style=\"text-align: justify;\"\u003eService note for JA-111A base\u003c\/h2\u003e    \u003ch3 style=\"text-align: justify;\"\u003eWired outdoor siren\u003c\/h3\u003e    \u003cp style=\"text-align: justify;\"\u003eThis product is part of the JABLOTRON JA-100 alarm system. The siren provides a visible and audible alarm indication outdoors. Other additional sound indications are also possible. The siren contains a backup battery that takes over in case of power failure. The product is intended to be installed by a trained technician with valid Jablotron certification. The product should be installed by a trained technician with a valid Jablotron certificate.\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e\u003cem\u003eInstallation\u003c\/em\u003e\u003cbr\u003e\u003cem\u003eThe\u003c\/em\u003e siren is mounted on a vertical wall, with the flash facing downwards. Avoid mounting near gutters and in places, where icing is likely.\u003cbr\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/handleiding%20100\/111a%201.jpg\" width=\"308\" height=\"457\"\u003e  \u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003ePicture: 1 - electroacoustic transducer; 2 - second electroacoustic transducer; 3 - NiCd battery; 4 - opening for supply cables; 5 - plate of electronics siren; 6 - liquid vial; 7 - holes for mounting siren on the wall; 8 - screw of siren cover; 9 - cable with clasp for securing cover of central unit (by pressing the drop-in clamp it can be easily disconnected)\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/handleiding%20100\/111a%202.jpg\" width=\"403\" height=\"279\"\u003e\u003cbr\u003eFigure: 10 - terminals of the BUS; 11 - key for learning; 12 - sabotage sensors; 13 - serial number; 14 - high-voltage transformer; 15 - very sharp shining signal lights of the flash; 16 - yellow signal light of malfunction; 17 - battery connection; 18 - connection electroacoustic transducer (attention, high voltage)\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e1. Open the outer cover of the siren (screw 8 down)\u003cbr\u003e2. Pull the bus cable through hole 4 in the rear part of the siren\u003cbr\u003e3. Screw the siren to the selected location using mounting holes 7 (2 screws), for determining the accurate vertical position of the siren, the integrated vial 6 can be used\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003eBefore connecting the BUS, the system must be disconnected from the power supply.\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e4. Connect the bus cable to the terminals (10).\u003cbr\u003e5. Plug the spare battery into the connector (17).\u003cbr\u003e6. Continue to follow the instructions for installing the central unit. Basic steps:\u003cbr\u003ea. After switching on, the yellow signal light (16) flashes because the siren is not assigned to the system.\u003cbr\u003eb. In the F-Link programme on the peripheral devices map, select the desired position and start learning mode with the Read button.\u003cbr\u003ec. Press the push button in the siren (11) - causing it to learn and the yellow light will extinguish.\u003cbr\u003e7. Reinstall the cover of the siren.\u003cbr\u003eSet properties\u003cbr\u003eThis is done by the F-Link programme - peripheral devices card. On position of the siren select Internal setting. A dialogue appears, allowing settings to be made:(* indicates the factory setting)\u003cbr\u003eSection: this determines which sections the siren will work for and possibly also signal entry\/exit delay and reinforcement. From the factory, the sound signal is set for all sections.*\u003cbr\u003eReaction: this determines, whether the siren will sound on signal EW* (warning outside) or IW (warning inside). The alarm sound can also be switched off completely (other functions are retained).\u003cbr\u003eSiren mooing: with interruptions*, without interruptions\u003cbr\u003eLimitation of mooing duration: 1, 2, 3*,4, 5 minutes.\u003cbr\u003eHarder sound: YES \/ NO* - this only affects signalling of entry\/exit delay and the sounds on contact of PG outputs.\u003cbr\u003eBeep sound on operation of sections: YES \/ NO* - if enabled, the siren beeps 1x on rearming, 2x on disarming and 3x on disarming after an alarm. Only for set sections.\u003cbr\u003eFlashing 30 minutes after alarm: YES \/ NO* the extended flashing (flashes) can be stopped by rearming the system or by cancelling alarm indication in the system (from the keypad).\u003cbr\u003eEvery 60 seconds a flash: YES \/ NO* optional indication of operation.\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eSound of PG outputs:\u003c\/strong\u003e\u003cbr\u003eA sound signal can be set for each PG output:\u003cbr\u003eSound 1 - slow beep 1 x per second (as long as the PG is switched on)\u003cbr\u003eSound 2 - fast beep 2 x per second (as long as the PG is switched on)\u003cbr\u003eSound 3 - 1x beep when the PG is switched on, 2 x when the PG is switched off\u003cbr\u003eSound 4 - long beep for 20 sec when the PG is switched on\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003ePriorities of siren operation:\u003c\/strong\u003e\u003cbr\u003eThe highest priority is for siren mooing, a lower priority is for beeping on operation, the lowest is the activity of the PG outputs (PG1 higher than PG2, etc.). The higher-priority sound always terminates the lower-priority sound.\u003cbr\u003eConnection to the control centre is disconnected\u003cbr\u003eIf the supply cable is disconnected, the siren will moo and flash for 3 minutes (this does not happen when the system is in service).\u003cbr\u003eTechnical parameters\u003cbr\u003ePower supply from the central unit BUS 12 V (9...15 V)\u003cbr\u003eCurrent consumption on standby (idle) 5 mA\u003cbr\u003eCurrent consumption for cable selection 50 mA\u003cbr\u003eBackup battery NiCd pack 4.8 V \/ 1800 mAh\u003cbr\u003eLifespan approx 3 roky\u003cbr\u003ePiezoelectric siren 110 dB\/m (with fully charged battery)\u003cbr\u003eDimensions 200 x 300 x 70 mm\u003cbr\u003eClassification grade 2\u003cbr\u003ecompliant with CSN EN 50131-1, CSN EN 50131-4\u003cbr\u003eEnvironmental class IV outdoors, general -25 to +60°C\u003cbr\u003eProtection degree IP34D\u003cbr\u003eComplies also with CSN EN 50130-4, CSN EN 55022, CSN EN 60950-1\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003eProduct JA-111A is designed and manufactured in accordance with the provisions to be applied to it: Government Decree No. 17\/2003 Sb. and 616\/2006 Sb., if used according to its intended use. Original declaration of conformity can be found at www.jablotron.cz in the advice section.\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Although this product does not contain harmful materials, do not dispose of it in domestic waste, but dispose of it at the collection point intended for electronic waste. \u003c\/p\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3315\/4025\/collections\/jablotron-ja-111a-bus-externe-sirene-base.jpg?v=1738735568","url":"https:\/\/www.nordskydd.se\/en\/collections\/ja-111a-base.oembed","provider":"alarmsysteemexpert","version":"1.0","type":"link"}